HT(Q) LO₂ Storage Tank – Efficient and Reliable Storage Solutions
Product Advantages
● Excellent thermal insulation properties: Our products have excellent thermal insulation properties, which effectively prevent heat transfer and ensure optimal temperature regulation.
● Innovative vacuum process: Our cutting-edge vacuum technology ensures that the product is free of any air or moisture, improving its overall performance and durability.
● Impeccable Piping System: We have crafted the perfect piping system to ensure the efficient and seamless flow of fluids, minimizing any interruptions or leaks. Mature
● Anti-corrosion coating: Our products adopt mature and reliable anti-corrosion coating, which Provides reliable anti-rust protection and prolongs its service life. Enhanced
● Safety Features: In addition to the above qualities, our products also contain enhanced safety features such as sturdy construction and secure fittings to ensure the utmost safety of the users.
Features
● Enhanced Security Measures: Our products are equipped with advanced security features such as biometric locks, encrypted data transmission and remote monitoring capabilities. These measures ensure maximum protection against unauthorized access and peace of mind for users.
● Simplified User Experience: We designed our products with user convenience in mind. From intuitive interfaces and user-friendly controls to automated processes and quick setup options, using our products is easy and simple.
● Reduce Loss & Waste: Our products use cutting-edge technology to minimize loss and waste. Whether through optimized energy efficiency, improved material utilization or advanced monitoring systems, our products help minimize resource waste and maximize yield.
● Simplified Maintenance: We understand how important simple maintenance is to our customers. Our products feature modular designs and removable components for easy troubleshooting and repair. In addition, we provide comprehensive maintenance guidelines and provide timely assistance to ensure smooth operation and minimize downtime.
Product Application
● Medical Industry: Our products play a vital role in the storage of liquefied gases used in medical applications such as cryogenic storage of vaccines, blood products and other temperature sensitive medical supplies. It ensures the safe preservation of these critical resources, maintaining their potency and quality.
● Machinery industry: Many industries rely on liquefied gas to power and cool machinery. Our products provide safe storage solutions for these gases, ensuring uninterrupted operation while adhering to the highest safety standards.
● Chemical industry: Liquefied gases are widely used in various chemical processes such as refrigeration and heating, and as raw materials for manufacturing. Our products provide a reliable and controlled environment to store these gases, prevent leaks and minimize the possibility of accidents.
● Food industry: liquefied gas is used for freezing, fresh-keeping, carbonation and other processes in the food industry. Our products ensure the safe storage of these gases, maintaining their purity and preventing contamination, thereby maintaining the quality and freshness of food.
● Aerospace Industry: In the aerospace industry, liquefied gases are used for propulsion, pressurization, and temperature control of rockets, satellites, and aircraft. Our products provide safe and efficient storage solutions for these volatile gases, ensuring maximum safety during transportation and use.
Overall, our products are critical storage solutions for liquefied gases in various industries, ensuring the safety, efficiency and quality of their operations.
Factory
Departure Site
Production site
Specification | Effective volume | Design pressure | Working pressure | Maximum allowable working pressure | Minimum design metal temperature | Vessel type | Vessel size | Vessel weight | Thermal insulation type | Static evaporation rate | Sealing vacuum | Design service life | Paint brand |
m³ | MPa | MPa | MPa | ℃ | / | mm | Kg | / | %/d(O₂) | Pa | Y | / | |
HT(Q)10/10 | 10.0 | 1.000 | <1.0 | 1.087 | -196 | Ⅱ | φ2166*2450*6200 | (4640) | Multi-layer winding | 0.220 | 0.02 | 30 | Jotun |
HT(Q)10/16 | 10.0 | 1.600 | <1.6 | 1.695 | -196 | Ⅱ | φ2166*2450*6200 | (5250) | Multi-layer winding | 0.220 | 0.02 | 30 | Jotun |
HTC10 | 10.0 | 2.350 | <2.35 | 2.446 | -40 | Ⅱ | φ2166*2450*6200 | 6330 | Multi-layer winding | ||||
HT(Q)15/10 | 15.0 | 1.000 | <1.0 | 1.095 | -196 | Ⅱ | φ2166*2450*7450 | (5925) | Multi-layer winding | 0.175 | 0.02 | 30 | Jotun |
HT(Q)15/16 | 15.0 | 1.600 | <1.6 | 1.642 | -196 | Ⅱ | φ2166*2450*7450 | (6750) | Multi-layer winding | 0.175 | 0.02 | 30 | Jotun |
HTC15 | 10.0 | 2.350 | <2.35 | 2.424 | -40 | Ⅱ | φ2166*2450*7450 | (8100) | Multi-layer winding | ||||
HT(Q)20/10 | 20.0 | 1.000 | <1.0 | 1.047 | -196 | Ⅱ | φ2516*2800*7800 | (7125) | Multi-layer winding | 0.153 | 0.02 | 30 | Jotun |
HT(Q)20/16 | 20.0 | 1.600 | <1.6 | 1.636 | -196 | Ⅱ | φ2516*2800*7800 | (8200) | Multi-layer winding | 0.153 | 0.02 | 30 | Jotun |
HTC20 | 10.0 | 2.350 | <2.35 | 2.435 | -40 | Ⅲ | φ2516*2800*7800 | 9720 | Multi-layer winding | ||||
HT(Q)30/10 | 30.0 | 1.000 | <1.0 | 1.097 | -196 | Ⅱ | φ2516*2800*10800 | (9630) | Multi-layer winding | 0.133 | 0.02 | 30 | Jotun |
HT(Q)30/16 | 30.0 | 1.600 | <1.6 | 1.729 | -196 | Ⅲ | φ2516*2800*10800 | (10930) | Multi-layer winding | 0.133 | 0.02 | 30 | Jotun |
HTC30 | 10.0 | 2.350 | <2.35 | 2.412 | -40 | Ⅲ | φ2516*2800*10800 | 13150 | Multi-layer winding | ||||
HT(Q)40/10 | 40.0 | 1.000 | <1.0 | 1.099 | -196 | Ⅱ | φ3020*3300*10000 | (12100) | Multi-layer winding | 0.115 | 0.02 | 30 | Jotun |
HT(Q)40/16 | 40.0 | 1.600 | <1.6 | 1.713 | -196 | Ⅲ | φ3020*3300*10000 | (13710) | Multi-layer winding | 0.115 | 0.02 | 30 | Jotun |
HT(Q)50/10 | 50.0 | 1.000 | <1.0 | 1.019 | -196 | Ⅱ | φ3020*3300*12025 | (15730) | Multi-layer winding | 0.100 | 0.03 | 30 | Jotun |
HT(Q)50/16 | 50.0 | 1.600 | <1.6 | 1.643 | -196 | Ⅲ | φ3020*3300*12025 | (17850) | Multi-layer winding | 0.100 | 0.03 | 30 | Jotun |
HTC50 | 10.0 | 2.350 | <2.35 | 2.512 | -40 | Ⅲ | φ3020*3300*12025 | 21500 | Multi-layer winding | ||||
HT(Q)60/10 | 60.0 | 1.000 | <1.0 | 1.017 | -196 | Ⅱ | φ3020*3300*14025 | (20260) | Multi-layer winding | 0.095 | 0.05 | 30 | Jotun |
HT(Q)60/16 | 60.0 | 1.600 | <1.6 | 1.621 | -196 | Ⅲ | φ3020*3300*14025 | (31500) | Multi-layer winding | 0.095 | 0.05 | 30 | Jotun |
HT(Q)100/10 | 100.0 | 1.000 | <1.0 | 1.120 | -196 | Ⅲ | φ3320*3600*19500 | (35300) | Multi-layer winding | 0.070 | 0.05 | 30 | Jotun |
HT(Q)100/16 | 100.0 | 1.600 | <1.6 | 1.708 | -196 | Ⅲ | φ3320*3600*19500 | (40065) | Multi-layer winding | 0.070 | 0.05 | 30 | Jotun |
HT(Q)150/10 | 150.0 | 1.000 | <1.0 | 1.044 | -196 | Ⅲ | φ3820*22500 | 43200 | Multi-layer winding | 0.055 | 0.05 | 30 | Jotun |
HT(Q)150/16 | 150.0 | 1.600 | <1.6 | 1.629 | -196 | Ⅲ | φ3820*22500 | 50200 | Multi-layer winding | 0.055 | 0.05 | 30 | Jotun |
Note:
1. The above parameters are designed to meet the parameters of oxygen, nitrogen and argon at the same time;
2. The medium can be any liquefied gas, and the parameters may be inconsistent with the table values;
3. The volume/dimensions can be any value and can be customized;
4. Q stands for strain strengthening, C refers to liquid carbon dioxide storage tank;
5. The latest parameters can be obtained from our company due to product updates.