Cryogenic Liquid Storage Tank MT-C | High-Quality Storage Solutions
Product Advantages
●Superior Thermal Performance: Both the perlite and composite Super Insulation™ systems provide excellent thermal insulation, minimizing heat transfer and ensuring superior thermal performance in your storage system.
●Extended Retention Time: The combination of double jacket construction and insulation system helps to extend the retention time of stored materials, reducing the need for frequent replenishment and ensuring stability and consistency.
●Minimize Life Cycle Costs: By choosing a perlite or composite Super Insulation™ system, you can minimize the life cycle costs associated with your storage system. The insulating nature of these systems reduces the energy required to maintain temperature, resulting in cost savings over the life of the system.
●Reduced Weight in Operating and Installation Expenses: The use of lightweight materials in the composite Super Insulation™ system helps reduce the overall weight of the storage system. Not only does this make transport and installation easier and more cost-effective, but it also reduces operating expenses related to system weight.
●Integrated Support and Lifting System: The double-jacketed construction of the storage system includes an integrated support and lifting system. This simplifies shipping and installation, saving time and reducing installation costs.
●Highly Corrosion Resistant Elastomeric Coatings: Elastomeric coatings used in storage system construction are highly resistant to corrosion, ensuring the longevity and durability of the system while also adhering to stringent environmental compliance standards. This helps prevent premature system deterioration and reduces the need for costly maintenance and repairs.
Product size
Our selection includes tanks of all sizes, ranging from 1500* to 264,000 US gallons (6,000 to 1,000,000 liters), ensuring we have the right size to meet your storage needs. Our tanks are designed to handle pressures from 175 to 500 psig (12 to 37 barg), giving you the flexibility to select a pressure rating to suit your specific requirements. Whatever your storage needs, we have the perfect tank size and pressure rating to meet them.
Product function
●Tailored to meet your specific application needs: Shennan's bulk cryogenic storage systems can be customized to provide a custom solution to meet your application's unique requirements. Whether you need to store liquids or gases, our systems can be designed to meet your specific needs.
●Comprehensive system solution packages: Our system solution packages include everything needed for efficient, reliable cryogenic storage. From storage tanks to delivery systems, we provide complete solutions to ensure first-class liquid or gas delivery.
●Maximize Process Efficiency: Our systems are designed to maximize process efficiency for efficient and reliable delivery of cryogenic liquids or gases. By optimizing the design and performance of our systems, we help you maximize process efficiency.
●Long-Term Integrity: Shennan's bulk cryogenic storage systems are built with long-term integrity in mind. We use high-quality materials and advanced manufacturing techniques to ensure that our systems are durable and reliable even under harsh operating conditions.
●Industry-Leading Efficiency: Our systems are designed to be efficient, helping you minimize operating costs and maximize productivity. By delivering superior performance and efficiency, our systems can help you achieve significant cost savings.
In conclusion, Shennan's bulk cryogenic storage systems are designed to be efficient, durable, and tailored to meet your specific application needs. With comprehensive system solution packages and a focus on long-term integrity and industry-leading efficiency, our systems deliver exceptional performance while maintaining low operating costs.
Factory
Departure Site
Production site
Specification | Effective volume | Design pressure | Working pressure | Maximum allowable working pressure | Minimum design metal temperature | Vessel type | Vessel size | Vessel weight | Thermal insulation type | Static evaporation rate | Sealing vacuum | Design service life | Paint brand |
m³ | MPa | Mpa | MPa | ℃ | / | mm | Kg | / | %/d(O₂) | Pa | Y | / | |
MT(Q)3/16 | 3.0 | 1.600 | <1.00 | 1.726 | -196 | Ⅱ | 1900*2150*2900 | (1660) | Multi-layer winding | 0.220 | 0.02 | 30 | Jotun |
MT(Q)3/23.5 | 3.0 | 2.350 | <2.35 | 2.500 | -196 | Ⅱ | 1900*2150*2900 | (1825) | Multi-layer winding | 0.220 | 0.02 | 30 | Jotun |
MT(Q)3/35 | 3.0 | 3.500 | <3.50 | 3.656 | -196 | Ⅱ | 1900*2150*2900 | (2090) | Multi-layer winding | 0.175 | 0.02 | 30 | Jotun |
MTC3/23.5 | 3.0 | 2.350 | <2.35 | 2.398 | -40 | Ⅱ | 1900*2150*2900 | (2215) | Multi-layer winding | 0.175 | 0.02 | 30 | Jotun |
MT(Q)5/16 | 5.0 | 1.600 | <1.00 | 1.695 | -196 | Ⅱ | 2200*2450*3100 | (2365) | Multi-layer winding | 0.153 | 0.02 | 30 | Jotun |
MT(Q)5/23.5 | 5.0 | 2.350 | <2.35 | 2.361 | -196 | Ⅱ | 2200*2450*3100 | (2595) | Multi-layer winding | 0.153 | 0.02 | 30 | Jotun |
MT(Q)5/35 | 5.0 | 3.500 | <3.50 | 3.612 | -196 | Ⅱ | 2200*2450*3100 | (3060) | Multi-layer winding | 0.133 | 0.02 | 30 | Jotun |
MTC5/23.5 | 5.0 | 2.350 | <2.35 | 2.445 | -40 | Ⅱ | 2200*2450*3100 | (3300) | Multi-layer winding | 0.133 | 0.02 | 30 | Jotun |
MT(Q)7.5/16 | 7.5 | 1.600 | <1.00 | 1.655 | -196 | Ⅱ | 2450*2750*3300 | (3315) | Multi-layer winding | 0.115 | 0.02 | 30 | Jotun |
MT(Q)7.5/23.5 | 7.5 | 2.350 | <2.35 | 2.382 | -196 | Ⅱ | 2450*2750*3300 | (3650) | Multi-layer winding | 0.115 | 0.02 | 30 | Jotun |
MT(Q)7.5/35 | 7.5 | 3.500 | <3.50 | 3.604 | -196 | Ⅱ | 2450*2750*3300 | (4300) | Multi-layer winding | 0.100 | 0.03 | 30 | Jotun |
MTC7.5/23.5 | 7.5 | 2.350 | <2.35 | 2.375 | -40 | Ⅱ | 2450*2750*3300 | (4650) | Multi-layer winding | 0.100 | 0.03 | 30 | Jotun |
MT(Q)10/16 | 10.0 | 1.600 | <1.00 | 1.688 | -196 | Ⅱ | 2450*2750*4500 | (4700) | Multi-layer winding | 0.095 | 0.05 | 30 | Jotun |
MT(Q)10/23.5 | 10.0 | 2.350 | <2.35 | 2.442 | -196 | Ⅱ | 2450*2750*4500 | (5200) | Multi-layer winding | 0.095 | 0.05 | 30 | Jotun |
MT(Q)10/35 | 10.0 | 3.500 | <3.50 | 3.612 | -196 | Ⅱ | 2450*2750*4500 | (6100) | Multi-layer winding | 0.070 | 0.05 | 30 | Jotun |
MTC10/23.5 | 10.0 | 2.350 | <2.35 | 2.371 | -40 | Ⅱ | 2450*2750*4500 | (6517) | Multi-layer winding | 0.070 | 0.05 | 30 | Jotun |
Note:
1. The above parameters are designed to meet the parameters of oxygen, nitrogen and argon at the same time;
2. The medium can be any liquefied gas, and the parameters may be inconsistent with the table values;
3. The volume/dimensions can be any value and can be customized;
4. Q stands for strain strengthening, C refers to liquid carbon dioxide storage tank;
5. The latest parameters can be obtained from our company due to product updates.